TEL-TRU CHECK-TEMP CALIBRATORS

Fast, easy to use, and accurate! The Tel-Tru Check-Temp Calibrator allows accurate verification of thermometer accuracy at the temperature point critical to the user's actual application. Environmental Safety and Health Professionals, Quality Assurance Managers and HACCP Coordinators in food processing/smoking, preparing/cooking, holding/serving and cooling/storage are using the Check-Temp Calibrator to verify the accuracy of their dial and digital thermometers.


The multi-hole Check-Temp Calibrators allow you to verify the accuracy of dial thermometers and digital probes of all sizes. They fit probes up to .250", .125", .187" and .375" diameter. Single hole Check-Temps fit probes up to .150" diameter. Custom hole diameters and custom temperature points available, please consult factory.

TO ORDER, REVIEW THE CHARTS BELOW AND
CHOOSE THE APPROPRIATE MODEL.
Order your re-certification here

 
As part of your HACCP Program, use Tel-Tru Check-Temp Calibrators to verify the accuracy of your food service and laboratory thermometers.

  • Verify the accuracy of dial thermometers and digital probes of all sizes
  • Optional factory re-certification and maintenance program
  • Built-in circuitry to warn if unit is more than 1°F out of calibration
  • Use with Dial Type thermometers - Built-in tool for holding the calibration nut makes adjustments fast and easy
  • Use with Digital Thermometers - Compare actual performance to accuracy specifications
  • Temperature Units - Check and calibrate at your critical temperature point
  • Accessories: Carrying case (padded Cordura® nylon); dial adjustment tool; cleaning brushes; tip sensitive probe adapter
  • Accuracy: ±0.2°F
  • Single-hole units: Fit probes up to .150" diameter
  • Multi-hole units: Fit probes up to .250", .125", .187" and .375" diameter
  • Certificate of Calibration: Traceable to NIST
  • Thank you for considering Tel-Tru’s Check-Temp Calibrator as your calibrating instrument! Please take a few moments to carefully review the listed items below for more information on using, caring, and re-certifying your calibrator.

  • Check-Temp Instructions – These basic instructions can be placed on top of the unit or you may post them on a wall near the unit’s placement. Review these instructions with all users of the Tel-Tru Check-Temp Calibrator.
  • Care and Use Instructions, Warranty – This form is an addendum to the basic instructions.
  • Order your Re-Certification – If your HACCP verification program requires annual re-certification, click here to order online. Or, you may use this Annual Re-Certification and Maintenance Notification Service (fill out and return the enclosed fax back form or call us for more information).
  • How to Pack your Calibrator – If you need to send your Check-Temp back for servicing or re-certification, please follow these instructions for safe shipment.
  • Additional Literature – See our Buyer's Guide and Check-Temp pricesheet for information on other Tel-Tru products and accessories.

  • SINGLE HOLE UNITS

    SPECS
    Setpoint140°F160°F212°F
    Accuracy±0.2°F±0.2°F±0.2°F
    Stability±0.06°F±0.06°F±0.06°F
    Heating TimeApprox. 8 min.Approx. 10 min.Approx. 10 min.
    Fits Probes Up To.150".150".150"
    Temp. Control ZoneDrawing ADrawing ADrawing A
    Voltage90 to 130 VAC, 50/60 Hz90 to 130 VAC, 50/60 Hz90 to 130 VAC, 50/60 Hz
    Power45 Watts45 Watts45 Watts
    Weight8.9 lbs.8.9 lbs.8.9 lbs.
    Housing MaterialStainless Steel 304SSStainless Steel 304SSStainless Steel 304SS
    Size3-1/16" H x 6-5/8" W x 10-7/8"D
    (78 mm x 168 x 276 mm)
    3-1/16" H x 6-5/8" W x 10-7/8"D
    (78 mm x 168 x 276 mm)
    3-1/16" H x 6-5/8" W x 10-7/8"D
    (78 mm x 168 x 276 mm)


    MULTI HOLE UNITS

    SPECS
    Setpoint40°F40°F and 160°F5°C and 90°C
    Accuracy±0.2°F±0.2°F±0.2°F
    Stability±0.09°F±0.07°F±0.07°F
    Heating TimeApprox. 3 min.Approx. 3 min.Approx. 3 min.
    Fits Probes Up To.250", .125", .187" and .375".250", .125", .187" and .375".250", .125", .187" and .375"
    Temp. Control ZoneDrawing ADrawing A

    Drawing A

    Voltage90 to 130 VAC, 50/60 Hz90 to 130 VAC, 50/60 Hz90 to 130 VAC, 50/60 Hz
    Power25 Watts25 Watts25 Watts
    Weight9.2 lbs.9.2 lbs.9.2 lbs.
    Housing MaterialStainless Steel 304SSStainless Steel 304SSStainless Steel 304SS
    Size3-1/16" H x 6-5/8" W x 10-7/8"D
    (78 mm x 168 x 276 mm)
    3-1/16" H x 6-5/8" W x 10-7/8"D
    (78 mm x 168 x 276 mm)
    3-1/16" H x 6-5/8" W x 10-7/8"D
    (78 mm x 168 x 276 mm)

    SPECS
    Setpoint40°F40°F and 160°F
    Accuracy±0.2°F±0.2°F
    Stability±0.09°F±0.07°F
    Heating TimeApprox. 3 min.Approx. 5 min.
    Fits Probes Up To.250", .125" and .187".250", .125" and .187"
    Temp. Control ZoneDrawing BDrawing B
    Voltage90 to 130 VAC, 50/60 Hz90 to 130 VAC, 50/60 Hz
    Power25 Watts25 Watts
    Weight9.2 lbs.9.2 lbs.
    Housing MaterialStainless Steel 304SSStainless Steel 304SS
    Size3-1/16" H x 6-5/8" W x 10-7/8"D
    (78 mm x 168 x 276 mm)
    3-1/16" H x 6-5/8" W x 10-7/8"D
    (78 mm x 168 x 276 mm)


    YOU MAY ALSO BE INTERESTED IN:


         Accessories

         Check-Temp