Now In: Transmitter Specifications for RTD Assemblies
HEAD MOUNT TRANSMITTER SPECIFICATIONS FOR RTD ASSEMBLIES
| Pt TMT180 Temperature head transmitter for resistance thermometer Pt100, adjustable via PC, for mounting in a connection head DIN Form B. - Universal PC programmable (PCP)
- 2 wire technology, 4 to 20 mA analog output
- High accuracy in total ambient temperature range
- Fault signal on sensor break or short circuit, NAMUR NE 43 compliant
- EMC to IEC 61 326-1, CE
- UL recognized component to UL 3111-1
- Ship building approval GL
- CSA General Purpose
- Configuration during measurement using configuration kit
- Customer specific measurement range setting
FIELD OF APPLICATION
- PC programmable (PCP) Temperature head transmitter for converting a Pt100 input signal into a scalable 4 to 20 mA analog output signal
- Input: Resistance thermometer (RTD) Pt100
- Configuration using a PC with TMT181A or TXU10-AA configuration kit (PC-software ReadWin® 2000)
For more detailed Pt TMT180 specifications, click here. |
|
 | HART® TMT182 Universal temperature head transmitter for resistance thermometers (RTD), thermocouples (TC), resistance and voltage transmitters, adjustable via HART protocol, for installation in a connection head DIN Form B. - Universal settings with HART protocol
- Operation, visualization and maintenance via PC, e. g. Fieldcare or ReadWin® 2000 operating software
- 2 wire technology, 4 to 20 mA analog output
- High accuracy in total ambient temperature range
- Fault signal on sensor break or short circuit, NAMUR NE 43 compliant
- EMC to NAMUR NE 21, CE
- UL recognized component to UL 3111-1
- Ex-Certification
- ATEX Ex ia and dust zone 22 in compliance with EN 50281-1 - FM IS - CSA IS - Galvanic isolation
- Output simulation
- Min./max. process value indicator function
- Customer specific linearization
- SIL2 compliant
FIELD OF APPLICATION - Temperature head transmitter with HART -protocol for converting various input signals into a scalable 4 to 20 mA analog output signal
- Input:
- Resistance thermometer (RTD) - Thermocouple (TC) - Resistance transmitter (Ohm) - Voltage transmitter (mV) - HART protocol for front end unit or panel unit operation using the hand operating module (DXR275, DXR375) or PC (e. g. ReadWin® 2000 or FieldCare)
For more detailed HART TMT182 specifications, click here. |
|
| | INTEGRATED TEMPERATURE TRANSMITTER SPECIFICATIONS ONLY for Series ST and NT RTD probe assemblies with integrated programmable compact transmitter
|
|
| ReadWin® is a registered trademark of Endress+Hauser. HART® is a registered trademark of the HART Communication Foundation. |